大气与环境光学学报 ›› 2021, Vol. 16 ›› Issue (4): 365-372.

• 光电技术 • 上一篇    

基于FPGA 的双通道旋转变压器测角系统设计

甘 戈1;2, 熊 伟1∗, 吴 洋1, 刘占才1, 刘景岩1;2, 朱双双1;2   

  1. 1 中国科学院合肥物质科学研究院安徽光学精密机械研究所, 中国科学院通用光学定标与表征技术重点实验室, 安徽 合肥 230031; 2 中国科学技术大学, 安徽 合肥 230036
  • 收稿日期:2020-04-24 修回日期:2020-05-29 出版日期:2021-07-28 发布日期:2021-07-28
  • 通讯作者: E-mail: frank@aiofm.ac.cn E-mail:frank@aiofm.ac.cn
  • 作者简介:甘 戈 (1993 - ), 安徽亳州人, 硕士研究生, 主要从事光电信息获取技术及地面检测设备开发方面的研究。 E-mail: gange521@163.com
  • 基金资助:
    Supported by Pre-Research Program of National Civil Space Technology of China (民用航天技术预先研究项目, D040102)

Design of Angle Measurement System of Two-Channel Rotary Transformer Based on FPGA

GAN Ge1;2, XIONG Wei1∗, WU Yang1, LIU Zhancai1, LIU Jingyan1;2, ZHU Shuangshuang1;2   

  1. 1 Key Laboratory of Optical Calibration and Characterization, Anhui Institute of Optics and Fine Mechanics, HFIPS, Chinese Academy of Sciences, Hefei 230031, China; 2 University of Science and Technology of China, Hefei 230026, China
  • Received:2020-04-24 Revised:2020-05-29 Published:2021-07-28 Online:2021-07-28
  • Contact: Wei /Xiong E-mail:frank@aiofm.ac.cn
  • Supported by:
    Pre-Research Program of National Civil Space Technology of China

摘要: 设计了用于星载设备的双通道多对极旋转变压器的角度测量系统。以获取高精度的电机旋转角度值为目的, 在旋转变压器测角工作原理、误差分析以及双通道数据组合算法和测角系统软硬件设计等方面进行了研究, 并选用 FPGA 对步进电机的角位移量进行探测与解算。为验证所设计的双通道旋变角度测量系统的精度, 采用了分辨率更高 的海德汉光电编码器进行同时采集, 并将两者数据进行对比, 结果表明新设计的测角系统误差小于30′′, 满足设计精度 指标。

关键词: 现场可编程逻辑门阵列, 双通道旋转变压器, 测角技术, 精度验证

Abstract: An angle measurement system of a two-channel rotary transformer for spaceborne equipment is designed. For the purpose of obtaining high precision motor rotation angle value, the principle, error analysis, data combination algorithm and the software and hardware design of the angle measurement system are studied, and FPGA is used to detect and calculate the angular displacement of the stepping motor. In order to verify the accuracy of the designed two-channel angle measurement system, a Heidenhain photoelectric encoder with higher resolution is used to collect the data at the same time. By comparing the two data, it is shown that the error of the designed angle measurement system is within 30′′, which meets the design accuracy requriements.