气溶胶粒子复折射指数的干涉光谱方法理论研究

气溶胶辐射强迫效应的正负在很大程度上取决于其复折射指数虚部的大小。运用干涉光谱和Mie散射理论,分别在相同粒径粒子和不同粒径粒子两种情况下,推导出了干涉光谱和气溶胶复折射指数之间的关系式,初步建立了干涉光谱方法测量气溶胶复折射指数的理论模型,并对探测限进行了讨论。研究表明:干涉光谱方法测量气溶胶的复折射指数在理论上是可行的。   

  1. (合肥工业大学仪器科学与光电工程学院,安徽 合肥 230009)
  • 收稿日期:2010-03-26 修回日期:2010-07-13 出版日期:2011-05-28 发布日期:2011-05-23
  • 通讯作者: 李保生(1974-),男,甘肃武威人,博士,副研究员。主要从事干涉测量方法、气溶胶测量等方面的研究。 E-mail:libaosheng@hfut.edu.cn
  • 作者简介:李保生(1974-),男,甘肃武威人,博士,副研究员。主要从事干涉测量方法、气溶胶测量等方面的研究。
  • 基金资助:

    教育部科学技术研究项目(108073)、合肥工业大学创新群体资助项目资助

Theoretical Investigation of Complex Refractive Index of Aerosols Particle Based on Interferometric Spectromemeter

Aerosols radiation forcing mostly depended on the imagery of complex refractive index. With interferometric spectrometer and Mie theoretics, the theoretical model of method of interferometric spectrometer for aerosols complex refractive index was built up in two conditions: similar radius particles and different radius particles, and the detections limit of complex refractive index is discussed at first glance. It shows that the complex refractive index of aerosols particle measured by interferometric interferometer is feasible and promising.   

  1. (School of Instrument Science and Opto-Electronics Engineering, Hefei University of Technology, Hefei 230009, China)
  • Received:2010-03-26 Revised:2010-07-13 Published:2011-05-28 Online:2011-05-23

摘要:

气溶胶辐射强迫效应的正负在很大程度上取决于其复折射指数虚部的大小。运用干涉光谱和Mie散射理论,分别在相同粒径粒子和不同粒径粒子两种情况下,推导出了干涉光谱和气溶胶复折射指数之间的关系式,初步建立了干涉光谱方法测量气溶胶复折射指数的理论模型,并对探测限进行了讨论。研究表明:干涉光谱方法测量气溶胶的复折射指数在理论上是可行的。

关键词: 气溶胶, 复折射指数, 干涉光谱

Abstract:

Aerosols radiation forcing mostly depended on the imagery of complex refractive index. With interferometric spectrometer and Mie theoretics, the theoretical model of method of interferometric spectrometer for aerosols complex refractive index was built up in two conditions: similar radius particles and different radius particles, and the detections limit of complex refractive index is discussed at first glance. It shows that the complex refractive index of aerosols particle measured by interferometric interferometer is feasible and promising.

Key words: aerosols, complex refractive index, interferometric spectrometer