Application of Monte Carlo Method in Colorimetric Temperature Measurement Under High Temperature Background Radiation

XIONG Danfeng1, LIU Chunhong1, WU Haibin2, ZHANG Lewen2   

  1. 1~School of Physics and Materials Engineering, Hefei Normal University, Hefei 230601, China; 2~School of Physics and Materials Science, Anhui University,Hefei 230601, China
  • Published:2019-05-17

Abstract: In colorimetric temperature measurement, high temperature background radiation interferes with the accurate measurement of target temperature. Monte Carlo method is used to simulate the emission position, radiation direction, reflection and absorption characteristics of background radiation by probability distribution. The radiant energy beam reflected by the target was detected by the detector and compared with the theoretical radiation difference to verify its accuracy. On this basis, a method that can eliminate the influence of high-temperature background radiation in a complex environment and improve the accuracy of temperature measurement is proposed.

Key words: high temperature background, Monte Carlo method, radiant energy beam, temperature measurement accuracy